Session aimJoint Experiment - AC / Gallium
Session day2007-10-29Operatorpduarte
Session IDISTTOK_20071029_2Coordinatorhf

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
164282007-10-29 18:35:17.058pduarte3.73.52740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. With Ga. Injector at r=60mm
164272007-10-29 18:25:15.417pduarte3.63.72740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. With Ga. Injector at r=60mm
164262007-10-29 18:16:37.553pduarte3.73.32740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. Withou Ga.
164252007-10-29 18:07:48.575pduarte3.63.82740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. With Ga. Injector at r=60mm
164242007-10-29 17:55:38.707pduarte3.73.72740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. Withou Ga.
164232007-10-29 17:46:16.256pduarte000ELCO failure. Ga Injector at r=60mm
164222007-10-29 17:38:56.595pduarte3.832740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. Withou Ga.
164212007-10-29 17:31:55.764pduarte3.83.22740 turns primary. R = 0,2ohm. ELCO = 200V. P=1,0x10^(-4)mbar. Pre-programmed H field and on V field. With Ga. Injector at r=65mm
164202007-10-29 17:19:57.061pduarte3.93.82740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,9x10^(-5)mbar. Pre-programmed H field and on V field. Without Ga.
164192007-10-29 17:12:08.636pduarte3.83.92740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,9x10^(-5)mbar. Pre-programmed H field and on V field. With Ga. Injector at r=65mm
164182007-10-29 17:04:11.603pduarte3.83.92740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,9x10^(-5)mbar. Pre-programmed H field and on V field. Ionic beam. Without Ga.
164172007-10-29 16:38:07.753pduarte3.93.92740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field. Ionic beam.
164162007-10-29 16:26:20.115pduarte3.93.92740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field. Ionic beam. SE30F has temperature detector from now on.
164152007-10-29 16:20:30.667pduarte3.93.92740 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field.
164142007-10-29 16:02:50.346pduarte000data acquisition problems
164132007-10-29 15:40:27.178pduarte3.747440 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field.
164122007-10-29 15:23:17.438pduarte3.93.99040 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field. AC
164112007-10-29 15:07:45.96pduarte43.97440 turns primary. R = 0,2ohm. ELCO = 200V. P=9,8x10^(-5)mbar. Pre-programmed H field and on V field.
164102007-10-29 14:50:19.927pduarte3.93.27440 turns primary. R = 0,2ohm. ELCO = 200V. P=9,7x10^(-5)mbar. Pre-programmed H field and on V field. RAKE=58mm, GUND=80mm, LANG=94mm for this session.