Session aimJoint Experiment - AC / Gallium
Session day2007-10-31Operatorpduarte
Session IDISTTOK_20071031_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
164992007-10-31 17:27:08.78pduarte000with Ga. without everything else (fields, etc). Temperature sensor on IONIC_TR512_B02.CHANNEL_0 for all this session. Injector at r=68mm
164982007-10-31 17:19:49.938pduarte3.632740 turns primary. R = 0,2ohm. ELCO = 190V. P=2,03x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=68mm. DC*
164972007-10-31 17:09:23.56pduarte3.632740 turns primary. R = 0,2ohm. ELCO = 190V. P=2,03x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=65mm. DC*
164962007-10-31 17:00:41.492pduarte3.53.22740 turns primary. R = 0,2ohm. ELCO = 190V. P=2,03x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=60mm. DC*
164952007-10-31 16:52:22.684pduarte3.63.35140 turns primary. R = 0,2ohm. ELCO = 190V. P=2,09x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=65mm. AC*
164942007-10-31 16:46:50.545pduarte000ELCO failure
164932007-10-31 16:37:47.254pduarte3.735140 turns primary. R = 0,2ohm. ELCO = 190V. P=2,07x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=65mm. AC*
164922007-10-31 16:31:38.843pduarte3.72.82740 turns primary. R = 0,2ohm. ELCO = 190V. P=2,06x10^(-4)mbar. Pre-programmed H field and on V field. without Ga. Injector at r=65mm.
164912007-10-31 16:21:46.905pduarte3.732740 turns primary. R = 0,2ohm. ELCO = 190V. P=1,96x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=65mm.
164902007-10-31 16:14:54.739pduarte3.635140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,88x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=62mm. AC*
164892007-10-31 16:08:52.167pduarte3.72.72740 turns primary. R = 0,2ohm. ELCO = 190V. P=1,87x10^(-4)mbar. Pre-programmed H field and on V field. without Ga. Injector at r=60mm.
164882007-10-31 16:02:24.033pduarte3.535140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,82x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=60mm. AC*
164872007-10-31 15:53:31.766pduarte3.535140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,79x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=58mm. AC*
164862007-10-31 15:45:09.031pduarte3.535140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,77x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=58mm. AC*
164852007-10-31 15:34:27.219pduarte3.635140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,74x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=59mm. AC*
164842007-10-31 15:24:18.43pduarte3.62.95140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,51x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=60mm. AC*
164832007-10-31 15:17:56.942pduarte3.42.52740 turns primary. R = 0,2ohm. ELCO = 190V. P=1,08x10^(-4)mbar. Pre-programmed H field and on V field. without Ga. Injector at r=60mm
164822007-10-31 15:10:05.855pduarte3.52.95140 turns primary. R = 0,2ohm. ELCO = 190V. P=1,00x10^(-4)mbar. Pre-programmed H field and on V field. with Ga. Injector at r=60mm. AC*
164812007-10-31 14:45:56.844pduarte3.52.95140 turns primary. R = 0,2ohm. ELCO = 190V. P=9,85x10^(-5)mbar. Pre-programmed H field and V field. Temperature sensor on IONIC_TR512_B02.CHANNEL_0 for this session. without Ga. Injector at r=60mm. AC*
164802007-10-31 14:38:17.243pduarte3.53.95140 turns primary. R = 0,2ohm. ELCO = 190V. P=9,70x10^(-5)mbar. Pre-programmed H field and on V field. Temperature sensor on IONIC_TR512_B02.CHANNEL_0 . without Ga. AC*
164792007-10-31 14:28:05.002pduarte33.55140 turns primary. R = 0,2ohm. ELCO = 190V. P=9,50x10^(-5)mbar. Pre-programmed H field and on V field.
164782007-10-31 14:04:00.778pduarte00040 turns primary. R = 0,2ohm. ELCO = 190V. P=9,50x10^(-5)mbar. Pre-programmed H field and on V field. acquisition problems