Session aimReal-Time plasma position control
Session day2007-01-16Operatorpduarte
Session IDISTTOK_2007116_1Coordinatorhf

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
139392007-01-16 17:34:22.781pduarte4.73.325Horizontal field and Vertical field.
139382007-01-16 17:26:40.267pduarte4.53.225Horizontal field and Vertical field.
139372007-01-16 17:16:35.78pduarte4.63.525 Mixed PI feedback on Horizontal field and pre-programed Vertical field.
139362007-01-16 17:11:07.572pduarte4.5325Mixed PI feedback on Horizontal field and pre-programed Vertical field.
139352007-01-16 16:37:08.929pduarte4.83.625Mixed PI feedback on Horizontal field and PI feedback on Vertical field.
139342007-01-16 16:25:14.478pduarte4.83.625Mixed PI feedback on Horizontal field and PI feedback on Vertical field.
139332007-01-16 16:12:09.48pduarte4.63.525Mixed P feedback on Horizontal field and P feedback on Vertical field.
139322007-01-16 15:59:22.926pduarte4.63.425Mixed P feedback on Horizontal field and P feedback on Vertical field.
139312007-01-16 15:54:05.293pduarte000ELCO failure
139302007-01-16 15:44:38.378pduarte4.53.525Mixed P feedback on Horizontal field and P feedback on Vertical field. PRECO off. ELCO=170V. R=0,2ohm
139292007-01-16 15:34:13.291pduarte43.425Mixed P feedback on Horizontal field and P feedback on Vertical field. PRECO off. ELCO=170V. R=0,2ohm
139282007-01-16 15:15:27.75pduarte3.52.828Mixed P feedback on Horizontal field and P feedback on Vertical field. PRECO off. ELCO=160V. R=0,2ohm
139272007-01-16 14:54:38.063pduarte005PRECO on. ELCO=60V. R=0,2ohm. System test.