Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 14394 | 2007-02-28 16:38:08.925 | pduarte | 4 | 3.1 | 31 | Cu-nD at position 33,5. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F measurement. |
| 14393 | 2007-02-28 16:27:11.135 | pduarte | 4.2 | 3.7 | 31 | Cu-nD at position 33,5. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14392 | 2007-02-28 16:16:48.669 | pduarte | 4.2 | 3.5 | 31 | Cu-nD at position 33,5. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14391 | 2007-02-28 16:07:10.54 | pduarte | 3.8 | 3 | 31 | Cu-nD at position 33,5. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14390 | 2007-02-28 15:57:28.739 | pduarte | 4.1 | 3 | 31 | Cu-nD at position 33. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14389 | 2007-02-28 15:48:37.186 | pduarte | 4.3 | 3 | 31 | Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14388 | 2007-02-28 15:42:13.71 | pduarte | 4.2 | 3 | 30 | Cu-nD at position 31. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14387 | 2007-02-28 15:31:57.154 | pduarte | 4.5 | 3 | 30 | P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. |
| 14386 | 2007-02-28 15:25:33.045 | pduarte | 4.3 | 2.9 | 30 | P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 10 mm. |
| 14385 | 2007-02-28 15:07:39.885 | pduarte | 4 | 3.1 | 30 | P Feedback on Horizontal field and on Vertical Field. |
| 14384 | 2007-02-28 14:59:51.323 | pduarte | 0 | 0 | 0 | wrong settings |