Session aimPosition tests
Session day2007-02-08Operatorpduarte
Session IDISTTOK_200728_1Coordinatorcsilva

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
142262007-02-08 17:46:50.496pduarte4.2225 R = 0,2. ELCO=160V. PRECO ON. P feedback on Horizontal field. Vertical position setpoint = 8. Positive step on Vertical field.
142252007-02-08 17:40:46.647pduarte3.82.130R = 0,2. ELCO=160V. PRECO ON. P feedback on Vertical field.
142242007-02-08 17:35:23.215pduarte41.230R = 0,2. ELCO=160V. PRECO ON. P feedback on Horizontal field. Vertical position setpoint = 8.
142232007-02-08 17:28:32.45pduarte4.12.230 R = 0,2. ELCO=160V. PRECO ON. P feedback on Horizontal field and on Vertical field. Vertical position setpoint = 8..
142222007-02-08 17:22:15.004pduarte42.230R = 0,2. ELCO=160V. PRECO ON. P feedback on Horizontal field. Vertical position setpoint = 8. Negative step on Vertical field.
142212007-02-08 17:13:52.97pduarte4.51.825R = 0,2. ELCO=160V. PRECO OFF. P feedback on Horizontal field. Vertical position setpoint = 8. Negative step on Vertical field.
142202007-02-08 17:01:29.816pduarte4.12.530negative step on Vertical field
142192007-02-08 16:55:30.632pduarte4.12.630negative step on Vertical field
142182007-02-08 16:48:20.74pduarte4.12.330Steps on vertical field
142172007-02-08 16:42:48.912pduarte4.12.730P feedback on horizontal. R=0,1ohms, ELCO = 150V. PRECO on. Vertical position setpoint = 15.
142162007-02-08 16:37:28.752pduarte42.529step on horizontal field
142152007-02-08 16:29:54.259pduarte4.52.830P feedback on horizontal. R=0,1ohms, ELCO = 150V. PRECO on. Vertical position setpoint = 8.
142142007-02-08 16:22:22.335pduarte4.52.830P feedback on horizontal and on Vertical field. R=0,1ohms, ELCO = 150V. PRECO on. Vert Kp = -123647. Horiz kp=3703647. Vertical position setpoint = 8.
142132007-02-08 16:07:29.898pduarte42.329P feedback on Vertical field and step on horizontal field. R=0,1ohms, ELCO = 150V. PRECO on. Vert Kp = -123647.
142122007-02-08 15:57:29.662pduarte42.329without position control.
142112007-02-08 15:47:38.272pduarte42.829R=0,1ohms, ELCO = 150V. PRECO on. without position control.
142102007-02-08 15:41:27.824pduarte4.32.816P feedback on Vertical field. R=0,1ohms, ELCO = 150V. PRECO on. Kp = 123647.
142092007-02-08 15:34:40.679pduarte4.12.830P feedback on Vertical field. R=0,1ohms, ELCO = 150V. PRECO on. Kp = -123647.
142082007-02-08 15:27:18.488pduarte4.52.325P feedback on Horizontal field and on Vertical field. R=0,1ohms, ELCO = 150V. PRECO on.
142072007-02-08 15:10:54.775pduarte4.1229P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V. PRECO on. Vertical position setpoint = -8 mm.
142062007-02-08 15:04:29.771pduarte4.3220P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V. PRECO on. Vertical position setpoint = 8 mm.
142052007-02-08 14:54:16.279pduarte4225P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V. PRECO on. Vertical position setpoint = 8 mm.
142042007-02-08 14:43:58.404pduarte4225P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V. PRECO on.
142032007-02-08 14:38:24.007pduarte000P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V.
142022007-02-08 14:32:30.308pduarte3.9227P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 150V.
142012007-02-08 14:23:06.371pduarte3.5227P feedback on Horizontal field and pre-programed step on Vertical field. R=0,2ohms, ELCO = 160V.