Session aimPosition tests R = 0,1
Session day2007-02-09Operatorpduarte
Session IDISTTOK_200729_1Coordinatorcsilva

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
142422007-02-09 16:45:45.595pduarte4.32.730R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field.
142412007-02-09 16:37:52.199pduarte4.32.930R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field.
142402007-02-09 16:30:29.381pduarte4.3330R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field.
142392007-02-09 16:20:18.559pduarte4.12.830R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field.
142382007-02-09 16:06:57.494pduarte42.430R = 0,1. ELCO=150V. PRECO ON. P feedback on Horizontal and on Vertical field. Vertical position setpoint = 18.
142372007-02-09 16:00:20.477pduarte4.52.530R = 0,1. ELCO=150V. PRECO ON. P feedback on Horizontal and on Vertical field. Vertical position setpoint = 10.
142362007-02-09 15:54:38.582pduarte4.12.725R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field.
142352007-02-09 15:47:07.129pduarte4.22.625R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field.
142342007-02-09 15:40:41.25pduarte42.825R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field.
142332007-02-09 15:31:56.681pduarte3.82.525R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field.
142322007-02-09 15:22:35.086pduarte42.525R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field.
142312007-02-09 15:16:12.001pduarte4.2325R = 0,1. ELCO=150V. PRECO OFF. P feedback on Vertical field and on Horizontal field. Vertical position setpoint = 15 mm
142302007-02-09 15:05:30.569pduarte52.825R = 0,1. ELCO=150V. PRECO OFF. P feedback on Vertical field. Kp = -123647. Negative step on Horizontal field.
142292007-02-09 15:00:10.151pduarte000wrong settings
142282007-02-09 14:54:06.629pduarte4.12.830R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Kp = -123647
142272007-02-09 14:48:15.763pduarte3.82.530R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Kp = -123647