Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 14242 | 2007-02-09 16:45:45.595 | pduarte | 4.3 | 2.7 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field. |
| 14241 | 2007-02-09 16:37:52.199 | pduarte | 4.3 | 2.9 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field. |
| 14240 | 2007-02-09 16:30:29.381 | pduarte | 4.3 | 3 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field. |
| 14239 | 2007-02-09 16:20:18.559 | pduarte | 4.1 | 2.8 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Pre-programed horizontal field. |
| 14238 | 2007-02-09 16:06:57.494 | pduarte | 4 | 2.4 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Horizontal and on Vertical field. Vertical position setpoint = 18. |
| 14237 | 2007-02-09 16:00:20.477 | pduarte | 4.5 | 2.5 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Horizontal and on Vertical field. Vertical position setpoint = 10. |
| 14236 | 2007-02-09 15:54:38.582 | pduarte | 4.1 | 2.7 | 25 | R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field. |
| 14235 | 2007-02-09 15:47:07.129 | pduarte | 4.2 | 2.6 | 25 | R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field. |
| 14234 | 2007-02-09 15:40:41.25 | pduarte | 4 | 2.8 | 25 | R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field. |
| 14233 | 2007-02-09 15:31:56.681 | pduarte | 3.8 | 2.5 | 25 | R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field. |
| 14232 | 2007-02-09 15:22:35.086 | pduarte | 4 | 2.5 | 25 | R = 0,1. ELCO=150V. PRECO OFF. Pre-programed Vertical field and Horizontal field. |
| 14231 | 2007-02-09 15:16:12.001 | pduarte | 4.2 | 3 | 25 | R = 0,1. ELCO=150V. PRECO OFF. P feedback on Vertical field and on Horizontal field. Vertical position setpoint = 15 mm |
| 14230 | 2007-02-09 15:05:30.569 | pduarte | 5 | 2.8 | 25 | R = 0,1. ELCO=150V. PRECO OFF. P feedback on Vertical field. Kp = -123647. Negative step on Horizontal field. |
| 14229 | 2007-02-09 15:00:10.151 | pduarte | 0 | 0 | 0 | wrong settings |
| 14228 | 2007-02-09 14:54:06.629 | pduarte | 4.1 | 2.8 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Kp = -123647 |
| 14227 | 2007-02-09 14:48:15.763 | pduarte | 3.8 | 2.5 | 30 | R = 0,1. ELCO=150V. PRECO ON. P feedback on Vertical field. Kp = -123647 |