Session aimCu-nD irradiation
Session day2007-03-01Operatorpduarte
Session IDISTTOK_200731_1Coordinatorhf

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
144232007-03-01 15:27:06.01pduarte3.72.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144222007-03-01 15:20:35.107pduarte3.72.631Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144212007-03-01 15:09:33.345pduarte3.82.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144202007-03-01 15:03:07.708pduarte3.82.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144192007-03-01 14:57:21.698pduarte3.82.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. Lights off.
144182007-03-01 14:50:16.01pduarte3.82.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. Lights off.
144172007-03-01 14:44:57.181pduarte3.82.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144162007-03-01 14:38:57.212pduarte3.72.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144152007-03-01 14:30:47.203pduarte3.72.731Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144142007-03-01 14:25:15.33pduarte3.72.631Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144132007-03-01 14:15:37.892pduarte3.62.531Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144122007-03-01 12:21:24.74pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144112007-03-01 12:15:36.386pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144102007-03-01 12:08:52.922pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144092007-03-01 12:02:38.641pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144082007-03-01 11:56:34.022pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144072007-03-01 11:49:46.437pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144062007-03-01 11:43:25.269pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144052007-03-01 11:37:14.662pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144042007-03-01 11:31:26.983pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
144032007-03-01 11:19:43.549pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F => V = -163V.
144022007-03-01 11:13:34.937pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F => V = -163V.
144012007-03-01 10:58:31.58pduarte42.831Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F.
144002007-03-01 10:47:48.329pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F.
143992007-03-01 10:32:56.32pduarte42.931Cu-nD at position 32. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F.
143982007-03-01 10:20:44.024pduarte42.731Cu-nD at position 31. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F.
143972007-03-01 10:07:46.638pduarte42.831Cu-nD at position 30. P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm. SE30F.
143962007-03-01 09:53:16.026pduarte42.831P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.
143952007-03-01 09:45:18.729pduarte3.82.731P Feedback on Horizontal field and on Vertical Field. Horizontal position setpoint = 8 mm.