Session aimMachine conditioning
Session day2007-04-24Operatorpduarte
Session IDISTTOK_2007424_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
148792007-04-24 13:47:24.558pduarte2.1230R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.40x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm.
148782007-04-24 13:41:44.442pduarte1.7225R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.50x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm.
148772007-04-24 13:35:43.944pduarte21.930R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.35x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm. *
148762007-04-24 13:30:24.281pduarte1.41.930R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.35x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm.
148752007-04-24 13:24:37.985pduarte1.2230 R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.3x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm.
148742007-04-24 13:18:41.571pduarte1.21.930R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.20x10^-4mbar. Z setpoint = -12mm and R setpoint = 20mm.