Session aimMachine conditioning
Session day2007-04-30Operatorpduarte
Session IDISTTOK_2007430_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
149232007-04-30 15:55:16.479pduarte1.21.522R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. Z setpoint = -10mm and R setpoint = 20mm.
149222007-04-30 15:49:48.552pduarte1.21.530R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. Z setpoint = -10mm and R setpoint = 20mm.
149212007-04-30 15:42:36.224pduarte1.21.527R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. Z setpoint = -8mm and R setpoint = 20mm.
149202007-04-30 15:36:49.104pduarte1.11.530R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. Z setpoint = -10mm and R setpoint = 25mm.
149192007-04-30 15:31:31.898pduarte11.56R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. R setpoint = 25mm.
149182007-04-30 15:25:46.627pduarte11.530R = 0,2ohm. ELCO = 150V. Mixed feedback on power supplies. P=1.30x10^-4mbar. Z setpoint = -5mm and R setpoint = 25mm.
149172007-04-30 14:20:15.243pduarte003R = 0,2ohm. ELCO = 150V. P=1.15x10^-4mbar.
149162007-04-30 14:14:14.444pduarte003R = 0,2ohm. ELCO = 150V. P=1.20x10^-4mbar.