Session aimMachine conditioning and Zeff
Session day2007-06-14Operatorpduarte
Session IDISTTOK_2007614_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
153372007-06-14 15:37:05.979pduarte2.52.42328 turns primary. R = 0,2ohm. ELCO = 160V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153362007-06-14 15:30:47.952pduarte2.52.52328 turns primary. R = 0,2ohm. ELCO = 160V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153352007-06-14 15:24:42.502pduarte2.42.52328 turns primary. R = 0,2ohm. ELCO = 160V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153342007-06-14 15:17:20.595pduarte2.32.22328 turns primary. R = 0,2ohm. ELCO = 160V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153332007-06-14 14:55:18.476pduarte2.73.21628 turns primary. R = 0,2ohm. ELCO = 180V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153322007-06-14 14:39:49.08pduarte2.53.21628 turns primary. R = 0,2ohm. ELCO = 180V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153312007-06-14 14:32:28.038pduarte2.33.11628 turns primary. R = 0,2ohm. ELCO = 180V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153302007-06-14 14:23:58.077pduarte2.23.11628 turns primary. R = 0,2ohm. ELCO = 180V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153292007-06-14 14:09:23.006pduarte2.13.11628 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153282007-06-14 11:33:42.896pduarte23.51528 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153272007-06-14 11:28:26.74pduarte1.63.51428 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153262007-06-14 11:21:51.508pduarte1.33.21128 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.
153252007-06-14 11:10:16.876pduarte0.150.153528 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.6x10^(-4)mbar. Pre-programed horizontal field.
153242007-06-14 11:03:34.513pduarte0.20.23528 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=1.5x10^(-4)mbar. Pre-programed horizontal field. AC