Session aimMachine conditioning and Ion Beam
Session day2007-06-20Operatorpduarte
Session IDISTTOK_2007620_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
154502007-06-20 16:41:42.698pduarte43.82528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154492007-06-20 16:35:59.183pduarte3.842528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154482007-06-20 16:30:23.426pduarte3.83.825 28 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154472007-06-20 16:24:46.354pduarte3.83.525 28 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154462007-06-20 16:18:53.647pduarte3.842528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154452007-06-20 16:13:13.34pduarte3.842528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154442007-06-20 16:07:30.044pduarte3.742528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154432007-06-20 16:02:08.849pduarte3.742528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154422007-06-20 15:56:44.25pduarte3.742528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154412007-06-20 15:51:17.035pduarte3.73.52528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154402007-06-20 15:45:51.151pduarte3.63.52528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154392007-06-20 15:40:27.292pduarte3.532528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154382007-06-20 15:34:36.601pduarte3.332528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154372007-06-20 15:29:08.33pduarte3.332528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154362007-06-20 15:23:24.268pduarte002ELCO failure
154352007-06-20 15:17:54.852pduarte3.332528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154342007-06-20 15:11:39.229pduarte3.232528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154332007-06-20 15:06:15.657pduarte2.92.82528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154322007-06-20 15:00:40.393pduarte2.72.82528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.4x10^(-4)mbar. Pre-programed horizontal field.
154312007-06-20 14:55:03.717pduarte2.52.62528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.35x10^(-4)mbar. Pre-programed horizontal field.
154302007-06-20 14:48:26.831pduarte22.62428 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.35x10^(-4)mbar. Pre-programed horizontal field.
154292007-06-20 14:42:42.352pduarte1.72.62328 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.35x10^(-4)mbar. Pre-programed horizontal field.
154282007-06-20 14:36:33.018pduarte1.42.62028 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.35x10^(-4)mbar. Pre-programed horizontal field.
154272007-06-20 14:30:51.401pduarte12.52528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.35x10^(-4)mbar. Pre-programed horizontal field.
154262007-06-20 14:24:50.875pduarte0.82.62528 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.3x10^(-4)mbar. Pre-programed horizontal field.