Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 15474 | 2007-06-21 15:52:05.928 | pduarte | 3.8 | 3.3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15473 | 2007-06-21 15:46:08.381 | pduarte | 3.9 | 3.2 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15472 | 2007-06-21 15:39:52.937 | pduarte | 3.7 | 3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.2x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15471 | 2007-06-21 15:33:35.686 | pduarte | 3.9 | 3.4 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15470 | 2007-06-21 15:28:06.806 | pduarte | 3.8 | 3.3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.0x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15469 | 2007-06-21 15:22:28.797 | pduarte | 3.9 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15468 | 2007-06-21 15:10:01.349 | pduarte | 3.9 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.0x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15467 | 2007-06-21 15:03:54.104 | pduarte | 3.9 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.0x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15466 | 2007-06-21 14:58:08.949 | pduarte | 3.7 | 3.3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.25x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15465 | 2007-06-21 14:52:28.276 | pduarte | 3.8 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15464 | 2007-06-21 14:46:54.729 | pduarte | 2.5 | 3 | 10 | FRAEP failure. 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15463 | 2007-06-21 14:41:05.729 | pduarte | 3.9 | 3.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15462 | 2007-06-21 14:34:46.118 | pduarte | 3.9 | 4 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15461 | 2007-06-21 14:28:46.698 | pduarte | 3.7 | 4 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. Probes at 31 cm. |
| 15460 | 2007-06-21 14:23:04.781 | pduarte | 3.7 | 4.2 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. |
| 15459 | 2007-06-21 14:16:51.506 | pduarte | 3.5 | 4.2 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. |
| 15458 | 2007-06-21 14:11:30.512 | pduarte | 3.3 | 4 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.1x10^(-5)mbar. Pre-programed horizontal field and feedback on vertical field. |
| 15457 | 2007-06-21 14:04:44.027 | pduarte | 2 | 2.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.0x10^(-5)mbar. Feedback on horizontal and vertical field. |
| 15456 | 2007-06-21 13:56:58.623 | pduarte | 2 | 2.5 | 22 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.0x10^(-5)mbar. Feedback on horizontal and vertical field. |
| 15455 | 2007-06-21 13:50:45.573 | pduarte | 2.5 | 4 | 22 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.5x10^(-5)mbar. Pre-programed horizontal field and feedback on Vertical field. |
| 15454 | 2007-06-21 13:34:21.743 | pduarte | 1.5 | 1.5 | 20 | 40 turns primary. R = 0,2ohm. ELCO = 200V. Magnetic probes on port 12. P=8.5x10^(-5)mbar. Pre-programed horizontal field. |
| 15453 | 2007-06-21 13:27:40.043 | pduarte | 0 | 0 | 2 | 40 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.2x10^(-4)mbar. Pre-programed horizontal field. |
| 15452 | 2007-06-21 13:15:24.649 | pduarte | 1 | 2.5 | 25 | 28 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.2x10^(-4)mbar. Pre-programed horizontal field. |
| 15451 | 2007-06-21 13:10:02.067 | pduarte | 0.8 | 2.5 | 25 | 28 turns primary. R = 0,2ohm. ELCO = 170V. Magnetic probes on port 12. P=1.05x10^(-4)mbar. Pre-programed horizontal field. |