| 15750 | 2007-07-10 15:54:58.766 | pduarte | 1.8 | 1.8 | 8 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.5x10^(-5)mbar. Pre-programed H and V field. Vertical power supply failure. |
| 15749 | 2007-07-10 15:44:08.282 | pduarte | 3.4 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.5x10^(-5)mbar. Pre-programed H and V field. |
| 15748 | 2007-07-10 15:37:39.42 | pduarte | 1.8 | 1.8 | 9 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.5x10^(-5)mbar. Pre-programed H and V field. Vertical power supply failure. |
| 15747 | 2007-07-10 15:26:58.796 | pduarte | 3.3 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.5x10^(-5)mbar. Pre-programed H and V field. |
| 15746 | 2007-07-10 15:16:16.667 | pduarte | 3.4 | 3.7 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.5x10^(-5)mbar. Pre-programed H and V field. |
| 15745 | 2007-07-10 15:08:46.196 | pduarte | 3.1 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.4x10^(-5)mbar. Pre-programed H and V field. |
| 15744 | 2007-07-10 15:01:53.222 | pduarte | 3 | 3.9 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.4x10^(-5)mbar. Pre-programed H and V field. |
| 15743 | 2007-07-10 14:54:19.772 | pduarte | 2.5 | 3.5 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.4x10^(-5)mbar. Pre-programed H and V field. |
| 15742 | 2007-07-10 14:47:15.054 | pduarte | 2 | 2.3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. |
| 15741 | 2007-07-10 14:19:23.957 | pduarte | 1.5 | 2 | 9 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. Vertical power supply failure |
| 15740 | 2007-07-10 14:12:30.562 | pduarte | 1.5 | 2 | 9 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. Vertical power supply failure |
| 15739 | 2007-07-10 14:02:03.543 | pduarte | 1.5 | 1.8 | 18 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. |
| 15738 | 2007-07-10 13:45:31.065 | pduarte | 1.5 | 2 | 18 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. |
| 15737 | 2007-07-10 13:34:51.462 | pduarte | 1.2 | 2.5 | 10 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. Vertical power supply failure |
| 15736 | 2007-07-10 13:24:27.933 | pduarte | 1.2 | 2 | 20 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.4x10^(-5)mbar. Pre-programed H and V field. |
| 15735 | 2007-07-10 13:13:04.067 | pduarte | 1.3 | 2.7 | 23 | 40 turns primary. R = 0,2ohm. ELCO = 210V. P=8.3x10^(-5)mbar. Pre-programed H and V field. |