Session aimMachine Conditioning. Bias. Ion Beam. RAKE & GUND
Session day2008-10-16Operatorpduarte
Session IDISTTOK_20081016_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
201232008-10-16 16:20:17.067pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=80mm. Electrode=60mm. VACPL=100V. *
201222008-10-16 16:12:59.421pduarte3.433040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=80mm. Electrode=60mm. VACPL=100V. *
201212008-10-16 16:04:36.417pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=80mm. Electrode=60mm. VACPL=100V. *
201202008-10-16 15:55:44.86pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=80mm. Electrode=60mm. VACPL=100V. *
201192008-10-16 15:46:47.715pduarte3.433040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=80mm. Electrode=60mm. VACPL=100V. *
201182008-10-16 15:40:16.143pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=75mm. Electrode=60mm. VACPL=100V. *
201172008-10-16 15:33:25.052pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=75mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201162008-10-16 15:27:46.617pduarte3.433040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. *
201152008-10-16 15:20:56.309pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201142008-10-16 15:14:49.164pduarte3.43.13040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201132008-10-16 15:09:06.205pduarte1.50.71040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Plasma Position node failure. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. Ion Beam.
201122008-10-16 15:02:26.763pduarte3.433040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201112008-10-16 14:56:06.234pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=65mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201102008-10-16 14:50:32.785pduarte3.52.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=70mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201092008-10-16 14:32:09.317pduarte000PRECO failure
201082008-10-16 14:26:10.298pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=70mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201072008-10-16 14:18:24.432pduarte3.52.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=70mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201062008-10-16 14:08:41.397pduarte3.533040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=70mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201052008-10-16 14:00:44.391pduarte3.53.33040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. GUND=75mm. Electrode=60mm. VACPL=100V. Ion Beam. *
201042008-10-16 13:53:17.775pduarte3.53.13040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. Electrode=60mm. VACPL=100V. Ion Beam.
201032008-10-16 13:46:15.15pduarte3.53.33040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. Electrode=60mm. VACPL=100V. Ion Beam. BAD RAKE
201022008-10-16 13:37:40.262pduarte3.43.63040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. Electrode=60mm. VACPL=100V. Ion Beam. BAD RAKE
201012008-10-16 13:31:15.832pduarte3.543040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,90x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62mm. Electrode=60mm. BAD RAKE
201002008-10-16 13:18:46.186pduarte4.54.53040 turns primary. R = 0,2ohm. ELCO = 180V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
200992008-10-16 13:12:52.438pduarte000PRECO failure
200982008-10-16 13:06:44.906pduarte453040 turns primary. R = 0,2ohm. ELCO = 200V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
200972008-10-16 13:00:04.233pduarte3.643040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
200962008-10-16 12:52:40.414pduarte2.32.63040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
200952008-10-16 12:46:56.535pduarte000PRECO failure