Session aimBias. RAKE, GUND, POLOIDAL
Session day2008-10-28Operatorpduarte
Session IDISTTOK_20081028_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
202882008-10-28 17:56:00.014pduarte3.42.83040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62. POLOIDAL=70. GUND=75mm. Electrode=60mm. VACPL=100V.
202872008-10-28 17:50:26.54pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62. POLOIDAL=65. GUND=75mm. Electrode=60mm. VACPL=100V.
202862008-10-28 17:44:07.46pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62. POLOIDAL=70. GUND=70mm. Electrode=60mm. VACPL=100V.
202852008-10-28 17:38:38.856pduarte3.433040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=62. POLOIDAL=75. GUND=70mm. Electrode=60mm. VACPL=100V.
202842008-10-28 17:33:02.628pduarte000PRECO failure
202832008-10-28 17:27:41.812pduarte000PRECO failure
202822008-10-28 17:22:16.123pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=66. POLOIDAL=80. GUND=70mm. Electrode=60mm. VACPL=100V.
202812008-10-28 17:16:21.988pduarte000PRECO failure
202802008-10-28 17:10:45.883pduarte000PRECO failure
202792008-10-28 17:04:56.001pduarte000PRECO failure
202782008-10-28 16:59:09.466pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=66. POLOIDAL=85. GUND=70mm. Electrode=60mm. VACPL=100V.
202772008-10-28 16:52:47.706pduarte3.33.13040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=70. POLOIDAL=90. GUND=70mm. Electrode=60mm. VACPL=100V.
202762008-10-28 16:47:18.495pduarte000PRECO failure
202752008-10-28 16:39:02.051pduarte3.43.23040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=70. POLOIDAL=95. Electrode=60mm. VACPL=100V.
202742008-10-28 16:33:28.655pduarte000PRECO failure
202732008-10-28 16:26:01.854pduarte3.43.63040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=70. POLOIDAL=95. Electrode=60mm.
202722008-10-28 16:10:53.994pduarte000PRECO failure
202712008-10-28 15:33:16.28pduarte000PRECO failure. o oscilloscopio trigou
202702008-10-28 15:27:42.333pduarte000PRECO failure. o oscilloscopio trigou
202692008-10-28 15:22:08.029pduarte000PRECO failure
202682008-10-28 15:15:02.662pduarte3.33.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. RAKE=70. POLOIDAL=95. Electrode=60mm.
202672008-10-28 15:07:12.594pduarte44.43040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. RAKE=70. POLOIDAL=95.
202662008-10-28 14:50:06.129pduarte000PRECO failure
202652008-10-28 14:40:28.787pduarte000PRECO failure
202642008-10-28 14:33:48.243pduarte000PRECO failure
202632008-10-28 14:27:34.103pduarte3.42.93040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
202622008-10-28 14:10:25.28pduarte21.81040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,60x10^(-4)mbar. Plasma Posiiton node failure.
202612008-10-28 14:03:17.991pduarte1.92.53040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.