Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 19919 | 2008-10-03 15:42:12.746 | pduarte | 0 | 0 | 0 | PRECO failure. TACSP failure. |
| 19918 | 2008-10-03 15:36:40.05 | pduarte | 3 | 3.1 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19917 | 2008-10-03 15:21:53.732 | pduarte | 3 | 3 | 24 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19916 | 2008-10-03 15:15:11.998 | pduarte | 0 | 0 | 0 | PRECO failure |
| 19915 | 2008-10-03 15:09:10.193 | pduarte | 3.7 | 4.5 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19914 | 2008-10-03 15:03:23.301 | pduarte | 0 | 0 | 0 | PRECO failure |
| 19913 | 2008-10-03 14:52:43.113 | pduarte | 3.9 | 4.5 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19912 | 2008-10-03 14:45:26.447 | pduarte | 3.5 | 4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19911 | 2008-10-03 14:38:46.014 | pduarte | 3.6 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19910 | 2008-10-03 14:33:08.192 | pduarte | 3.6 | 3.2 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19909 | 2008-10-03 14:26:36.853 | pduarte | 0 | 0 | 0 | PRECO failure |
| 19908 | 2008-10-03 14:20:34.209 | pduarte | 3.6 | 3.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19907 | 2008-10-03 14:11:23.247 | pduarte | 3.5 | 3.75 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19906 | 2008-10-03 14:05:22.783 | pduarte | 3.1 | 3.5 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19905 | 2008-10-03 13:58:25.821 | pduarte | 2.6 | 3.1 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19904 | 2008-10-03 13:43:31.068 | pduarte | 0 | 0 | 0 | PRECO failure |
| 19903 | 2008-10-03 13:36:44.196 | pduarte | 2.2 | 2.9 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19902 | 2008-10-03 13:29:12.363 | pduarte | 1.8 | 2.9 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 19901 | 2008-10-03 13:20:04.303 | pduarte | 1.4 | 2.5 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 19900 | 2008-10-03 13:00:08.067 | pduarte | 0 | 0 | 2 | 40 turns primary. R = 0,2ohm. ELCO = 150V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |