Session aimMachine conditioning, Ion beam tests
Session day2008-01-11Operatorpduarte
Session IDISTTOK_2008111_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
173612008-01-11 16:22:08.946pduarte000Software shot - power supplies test (battery test)
173602008-01-11 16:16:00.308pduarte000Software shot - power supplies test (battery test)
173592008-01-11 16:12:11.411pduarte000Software shot - power supplies test (battery test)
173582008-01-11 15:57:45.706pduarte000Software shot - power supplies test (battery test)
173572008-01-11 15:41:34.94pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173562008-01-11 15:35:31.468pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173552008-01-11 15:29:32.784pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173542008-01-11 15:23:03.964pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173532008-01-11 15:16:35.981pduarte2.73.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173522008-01-11 15:10:16.618pduarte000ELCO failure
173512008-01-11 15:02:00.489pduarte2.73.37240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173502008-01-11 14:56:21.705pduarte2.53.27240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173492008-01-11 14:50:19.745pduarte2.33.37240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173482008-01-11 14:43:32.631pduarte1.63.27240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173472008-01-11 14:37:33.48pduarte1.337240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,54x10^(-4)mbar. Pre-programmed H field and V field.
173462008-01-11 14:30:39.626pduarte1.337240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-programmed H field and V field.
173452008-01-11 14:23:38.188pduarte1.237240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-programmed H field and V field.
173442008-01-11 14:17:08.58pduarte137240 turns primary. R = 0,2ohm. ELCO = 200V. P=9,75x10^(-4)mbar. Pre-programmed H field and V field.
173432008-01-11 14:05:13.867pduarte000Software shot - Plasma Position node test
173422008-01-11 13:59:33.636pduarte000Software shot - Plasma Position node test