Session aimMachine conditioning
Session day2008-01-14Operatorpduarte
Session IDISTTOK_2008114_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
173762008-01-14 16:13:34.722pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-programmed H field and V field. STEPS on IVERT.
173752008-01-14 16:05:44.776pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-programmed H field and V field. STEPS on IVERT.
173742008-01-14 15:56:16.421pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-programmed H field and V field. STEPS on IVERT.
173732008-01-14 15:50:11.131pduarte331540 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-programmed H field and V field. Power supplies did not stop
173722008-01-14 15:40:05.152pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-programmed H field and V field.
173712008-01-14 15:28:47.041pduarte33.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173702008-01-14 15:21:47.191pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173692008-01-14 15:14:03.754pduarte33.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173682008-01-14 15:04:50.675pduarte2.73.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-programmed H field and V field.
173672008-01-14 14:56:45.022pduarte000Power supplies controler failure
173662008-01-14 14:50:32.268pduarte2.83.37040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173652008-01-14 14:40:48.739pduarte2.43.17040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-programmed H field and V field.
173642008-01-14 14:34:50.419pduarte1.937040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-programmed H field and V field.
173632008-01-14 14:29:08.902pduarte1.537040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,15x10^(-4)mbar. Pre-programmed H field and V field.
173622008-01-14 14:19:58.332pduarte12.97040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-programmed H field and V field.