Session aimMachine conditioning, Zeff & Spectrometer tests
Session day2008-01-22Operatorpduarte
Session IDISTTOK_2008122_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
174992008-01-22 17:32:03.085pduarte2.52.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,84x10^(-4)mbar. Pre-Programmed H field and V field.
174982008-01-22 17:26:23.47pduarte2.52.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,81x10^(-4)mbar. Pre-Programmed H field and V field.
174972008-01-22 17:20:23.734pduarte2.52.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,77x10^(-4)mbar. Pre-Programmed H field and V field.
174962008-01-22 17:14:48.919pduarte2.52.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,73x10^(-4)mbar. Pre-Programmed H field and V field.
174952008-01-22 17:09:09.759pduarte2.32.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed H field and V field.
174942008-01-22 17:02:37.52pduarte2.32.76340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Mixed-Feedback on H field and Pre-programmed V field.
174932008-01-22 16:57:06.686pduarte2.52.76440 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Mixed-Feedback on H field and Pre-programmed V field.
174922008-01-22 16:49:14.585pduarte2.52.76340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Mixed-Feedback on H field and Pre-programmed V field.
174912008-01-22 16:41:39.705pduarte22.75640 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and Pre-programmed V field.
174902008-01-22 16:33:38.493pduarte22.75640 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and Pre-programmed V field.
174892008-01-22 16:23:19.515pduarte22.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174882008-01-22 16:16:32.554pduarte1.82.56240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174872008-01-22 16:04:06.288pduarte22.56240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174862008-01-22 15:57:59.588pduarte1.82.56240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174852008-01-22 15:52:07.959pduarte1.52.54640 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174842008-01-22 15:41:38.689pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field. new Vloop on gund 8
174832008-01-22 15:33:33.016pduarte000ELCO failure
174822008-01-22 15:24:47.577pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174812008-01-22 15:13:29.09pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field. New Vloop calibration on gund 8 with 14,54 V of Vin
174802008-01-22 15:05:31.47pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field. New Vloop calibration on gund 8 with 14,55 V of Vin
174792008-01-22 14:58:30.309pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174782008-01-22 14:40:45.283pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174772008-01-22 14:25:38.925pduarte1.52.56340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Mixed-Feedback on H field and on V field.
174762008-01-22 14:14:55.243pduarte12.56140 turns primary. R = 0,2ohm. ELCO = 200V. P=9,85x10^(-5)mbar. Mixed-Feedback on H field and on V field.