Session aimMachine Conditioning, Gundestrup tests
Session day2008-01-23Operatorpduarte
Session IDISTTOK_2008123_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
175242008-01-23 17:57:53.964pduarte2.52.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175232008-01-23 17:52:01.188pduarte000ELCO failure
175222008-01-23 17:44:47.754pduarte2.52.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175212008-01-23 17:29:51.527pduarte2.52.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175202008-01-23 17:23:37.006pduarte000ELCO failure
175192008-01-23 17:09:14.137pduarte2.52.97240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,46x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175182008-01-23 16:41:44.376pduarte2.52.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,46x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175172008-01-23 16:32:07.674pduarte2.42.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,46x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175162008-01-23 16:26:34.807pduarte2.42.87240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,46x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175152008-01-23 16:20:07.642pduarte2.537240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175142008-01-23 16:12:02.523pduarte1.52.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,45x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175132008-01-23 15:59:41.654pduarte1.32.77240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,35x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG.
175122008-01-23 15:54:05.40pduarte000ELCO failure
175112008-01-23 15:47:06.135pduarte12.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H field and V field. Gundestrup on LANG
175102008-01-23 15:40:02.374pduarte002wrong settings on IVERT