Session aimMachine conditioning
Session day2008-01-29Operatorpduarte
Session IDISTTOK_2008129_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
175872008-01-29 18:08:52.401pduarte2.82.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field.
175862008-01-29 18:02:29.229pduarte2.82.67240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field.
175852008-01-29 17:39:42.743pduarte2.72.67240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H field and V field.
175842008-01-29 17:27:12.657pduarte31840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed H field and V field. FRAEP failure.
175832008-01-29 16:49:26.361pduarte2.82.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed H field and V field.
175822008-01-29 16:26:55.534pduarte2.92.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,62x10^(-4)mbar. Pre-Programmed H field and V field.
175812008-01-29 16:07:52.704pduarte2.92.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-Programmed H field and V field. Ion beam.
175802008-01-29 15:59:28.809pduarte2.92.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-Programmed H field and V field. Ion beam.
175792008-01-29 15:48:59.092pduarte2.82.57240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,55x10^(-4)mbar. Pre-Programmed H field and V field. Ion beam.
175782008-01-29 15:38:27.378pduarte2.72.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,65x10^(-4)mbar. Pre-Programmed H field and V field. IVERT was changed from VME to TR512_TOMOGRAPHY_TR512_B06.CHANNEL_5
175772008-01-29 15:30:35.532pduarte2.52.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,25x10^(-4)mbar. Pre-Programmed H field and V field. IVERT was changed from VME to TR512_TOMOGRAPHY_TR512_B06.CHANNEL_5
175762008-01-29 15:15:42.397pduarte2.72.53840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,23x10^(-4)mbar. Pre-Programmed H field and V field.
175752008-01-29 15:08:34.627pduarte22.47240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,23x10^(-4)mbar. Pre-Programmed H field and V field.
175742008-01-29 15:01:51.349pduarte1.72.56040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,15x10^(-4)mbar. Pre-Programmed H field and V field. Plasma Position node failure.
175732008-01-29 14:53:35.77pduarte12.17240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,04x10^(-4)mbar. Pre-Programmed H field and V field.