Session aimMachine conditioning
Session day2008-02-25Operatorpduarte
Session IDISTTOK_2008225_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
178162008-02-25 17:29:23.379pduarte12.42140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Electrode Gate-valve openned.
178152008-02-25 17:23:54.98pduarte0.952.352140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Electrode Gate-valve openned.
178142008-02-25 17:15:04.51pduarte0.92.32140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178132008-02-25 17:09:12.864pduarte0.82.32140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178122008-02-25 17:02:50.258pduarte0.82.32140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178112008-02-25 16:54:56.736pduarte0.71.82140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178102008-02-25 16:49:18.057pduarte0.651.82140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,15x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178092008-02-25 16:43:30.458pduarte0.551.72140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,05x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178082008-02-25 16:37:47.082pduarte0.31.52040 turns primary. R = 0,2ohm. ELCO = 230V. P=1,07x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed. After Manual Clean.
178072008-02-25 15:36:49.612pduarte12.52140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed.
178062008-02-25 15:31:23.795pduarte122140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed.
178052008-02-25 15:22:16.071pduarte1.11.92140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed.
178042008-02-25 15:15:50.416pduarte11.92140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed.
178032008-02-25 15:08:52.46pduarte11.92140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Gate-valves closed.
178022008-02-25 14:57:11.305pduarte00140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=32khz and acq freq=200kHz. IVERT=0A
178012008-02-25 14:50:54.242pduarte001ELCO failure
178002008-02-25 14:41:42.832pduarte0.951.82140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=32khz and acq freq=200kHz.
177992008-02-25 14:35:14.214pduarte0.81.82140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=32khz and acq freq=200kHz.
177982008-02-25 14:29:13.417pduarte0.751.72140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,10x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=16khz and acq freq=200kHz.
177972008-02-25 14:18:24.764pduarte0.71.72140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,05x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=8khz and acq freq=200kHz.
177962008-02-25 14:10:50.258pduarte0.51.752140 turns primary. R = 0,2ohm. ELCO = 230V. P=1,05x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=8khz and acq freq=200kHz.
177952008-02-25 14:00:47.976pduarte0.51.42040 turns primary. R = 0,2ohm. ELCO = 230V. P=1,03x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=8khz and acq freq=100kHz.
177942008-02-25 13:53:32.049pduarte0.312040 turns primary. R = 0,2ohm. ELCO = 230V. P=1,00x10^(-4)mbar. Pre-Programmed H field and V field. Interferometer filter=8khz and acq freq=100kHz.