Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 17863 | 2008-02-27 17:09:42.624 | pduarte | -1.9 | 3.4 | 37 | PRECO failure. 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17862 | 2008-02-27 17:02:13.822 | pduarte | -1.9 | 3.4 | 17 | PRECO failure. 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17861 | 2008-02-27 16:56:14.876 | pduarte | 1.9 | 3.5 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17860 | 2008-02-27 16:45:51.846 | pduarte | 1.9 | 3.4 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17859 | 2008-02-27 16:38:21.778 | pduarte | 1.7 | 3.4 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17858 | 2008-02-27 16:31:50.239 | pduarte | 1.7 | 3.2 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17857 | 2008-02-27 16:24:57.868 | pduarte | 1.7 | 3.2 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,20x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17856 | 2008-02-27 15:59:53.228 | pduarte | 1.6 | 3 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17855 | 2008-02-27 15:53:08.33 | pduarte | 1.5 | 3 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,17x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17854 | 2008-02-27 15:35:02.011 | pduarte | 1.35 | 3 | 35 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,15x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17853 | 2008-02-27 14:45:44.266 | pduarte | 1.3 | 2.9 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,15x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17852 | 2008-02-27 14:16:14.959 | pduarte | 1.1 | 2.9 | 37 | 40 turns primary. R = 0,2ohm. ELCO = 230V. P=1,15x10^(-4)mbar. Pre-Programmed H field and V field. |
| 17851 | 2008-02-27 14:10:06.635 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure |