Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
185002008-04-23 15:24:32.946pduarte2.453.13040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184992008-04-23 15:17:39.492pduarte2.453.13040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184982008-04-23 15:09:55.63pduarte2.4533040 turns primary. R = 0,2ohm. ELCO = 220V. P=0,90x10^(-4)mbar. Pre-Programmed H and V field.
184972008-04-23 15:03:20.908pduarte2.433040 turns primary. R = 0,2ohm. ELCO = 220V. P=0,85x10^(-4)mbar. Pre-Programmed H and V field.
184962008-04-23 14:57:15.758pduarte2.32.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=0,85x10^(-4)mbar. Pre-Programmed H and V field.
184952008-04-23 14:50:52.342pduarte2.22.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=0,85x10^(-4)mbar. Pre-Programmed H and V field.
184942008-04-23 14:44:38.307pduarte2.133040 turns primary. R = 0,2ohm. ELCO = 220V. P=0,85x10^(-4)mbar. Pre-Programmed H and V field.
184932008-04-23 14:39:00.254pduarte2.12.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184922008-04-23 14:32:38.876pduarte22.930 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184912008-04-23 14:11:54.141pduarte000ELCO circuit breaker failure
184902008-04-23 14:06:10.178pduarte22.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184892008-04-23 13:59:26.365pduarte1.82.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184882008-04-23 13:49:34.416pduarte000Aborted
184872008-04-23 13:43:22.964pduarte000ELCO circuit breaker failure
184862008-04-23 13:36:11.31pduarte22.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184852008-04-23 13:30:10.072pduarte22.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184842008-04-23 13:21:45.068pduarte22.93040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184832008-04-23 13:15:52.095pduarte1.92.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184822008-04-23 13:09:13.008pduarte1.82.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184812008-04-23 13:00:49.514pduarte1.72.73040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184802008-04-23 11:02:08.317pduarte1.733040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184792008-04-23 10:56:34.247pduarte1.72.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184782008-04-23 10:48:53.355pduarte1.72.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184772008-04-23 10:42:21.081pduarte1.62.83040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184762008-04-23 10:35:42.77pduarte1.52.73040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184752008-04-23 10:27:45.497pduarte1.52.63040 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184742008-04-23 10:20:49.917pduarte1.32.43040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184732008-04-23 10:13:40.583pduarte1.32.33040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184722008-04-23 10:07:38.586pduarte1.22.33040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.
184712008-04-23 10:01:50.465pduarte1.12.23040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field.