Session aimMachine conditioning. Ion Beam tests
Session day2008-04-03Operatorpduarte
Session IDISTTOK_200843_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
181402008-04-03 15:40:51.593pduarte001ELCO circuit breaker failure
181392008-04-03 15:35:00.756pduarte002Plasma Position node failure
181382008-04-03 15:28:39.325pduarte2.92.62640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181372008-04-03 15:21:14.515pduarte2.52.52640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,25x10^(-4)mbar. Pre-Programmed H and V field.
181362008-04-03 15:12:24.371pduarte2.42.52640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,25x10^(-4)mbar. Pre-Programmed H and V field.
181352008-04-03 15:06:03pduarte22.42640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,34x10^(-4)mbar. Pre-Programmed H and V field.
181342008-04-03 14:59:57.491pduarte000ELCO circuit breaker failure
181332008-04-03 14:52:45.285pduarte2.12.52640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
181322008-04-03 14:46:57.658pduarte232040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
181312008-04-03 14:40:28.394pduarte232040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
181302008-04-03 14:32:55.188pduarte002Plasma Position node failure
181292008-04-03 14:26:12.13pduarte2.83.12640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
181282008-04-03 14:20:18.702pduarte2.93.12640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181272008-04-03 14:13:46.928pduarte2.73.12640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181262008-04-03 14:07:11.712pduarte2.42.72640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181252008-04-03 14:00:37.271pduarte00140 turns primary. R = 0,2ohm. ELCO = 50V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181242008-04-03 13:44:48.951pduarte000failure
181232008-04-03 13:30:34.702pduarte3.23.22640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. IIGBT stop trigger failure.
181222008-04-03 13:22:02.599pduarte3.23.12640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181212008-04-03 13:13:47.695pduarte3.134940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181202008-04-03 13:06:44.949pduarte2.62.64940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181192008-04-03 13:00:24.407pduarte2.32.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181182008-04-03 12:54:16.593pduarte1.82.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181172008-04-03 12:47:22.962pduarte1.62.44940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181162008-04-03 12:41:06.672pduarte1.22.44940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,06x10^(-4)mbar. Pre-Programmed H and V field.
181152008-04-03 12:35:38.853pduarte124940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,06x10^(-4)mbar. Pre-Programmed H and V field.
181142008-04-03 12:29:43.079pduarte-12.41040 turns primary. R = 0,2ohm. ELCO = 180V. P=1,03x10^(-4)mbar. Pre-Programmed H and V field.