Session aim Machine conditioning. Ion Beam tests
Session day2008-04-04Operatorpduarte
Session IDISTTOK_200844_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
181592008-04-04 14:46:49.344pduarte3.63.64940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181582008-04-04 14:32:13.672pduarte3.53.64940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181572008-04-04 14:21:15.147pduarte3.53.52640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181562008-04-04 14:12:18.217pduarte3.93.94940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181552008-04-04 14:04:23.068pduarte3.544940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181542008-04-04 13:52:11.376pduarte3.544940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181532008-04-04 13:44:53.114pduarte3.53.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181522008-04-04 13:37:08.169pduarte3.744940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181512008-04-04 13:30:12.835pduarte3.93.64940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181502008-04-04 13:24:15.498pduarte3.53.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181492008-04-04 13:16:38.027pduarte3.93.64940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181482008-04-04 13:09:43.365pduarte3.73.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181472008-04-04 13:02:22.864pduarte3.53.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181462008-04-04 12:55:36.214pduarte334940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field.
181452008-04-04 12:49:45.657pduarte2.42.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181442008-04-04 12:42:37.021pduarte1.62.34440 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181432008-04-04 12:36:19.393pduarte12.34940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181422008-04-04 12:28:50.874pduarte001Plasma Position node failure
181412008-04-04 12:22:42.14pduarte001ELCO circuit breaker failure