Session aimMachine conditioning. Ion Beam tests
Session day2008-04-07Operatorpduarte
Session IDISTTOK_200847_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
181772008-04-07 16:33:12.619pduarte342640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field. Horizontal power supply without analog filter.
181762008-04-07 16:26:57.405pduarte334940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field. Horizontal power supply without analog filter.
181752008-04-07 16:20:32.667pduarte33.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field. Horizontal power supply without analog filter.
181742008-04-07 16:10:41.279pduarte3.33.24940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field. Horizontal power supply without analog filter.
181732008-04-07 15:47:21.774pduarte3.23.24940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181722008-04-07 15:30:42.601pduarte001ELCO didn t charged
181712008-04-07 15:24:10.213pduarte332640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181702008-04-07 15:18:07.70pduarte3.334940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181692008-04-07 15:11:55.876pduarte3.334940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181682008-04-07 15:05:34.116pduarte3.334940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181672008-04-07 14:57:48.43pduarte2.834940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181662008-04-07 14:51:05.473pduarte2.72.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,08x10^(-4)mbar. Pre-Programmed H and V field.
181652008-04-07 14:42:38.649pduarte2.52.54940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181642008-04-07 14:34:35.441pduarte1.72.34940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181632008-04-07 14:25:48.349pduarte1.52.24240 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181612008-04-07 14:10:46.423pduarte0.924940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.
181602008-04-07 14:04:58.581pduarte0.524940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,05x10^(-4)mbar. Pre-Programmed H and V field.