Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 18733 | 2008-05-12 16:31:14.716 | pduarte | 5.5 | 4.2 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18732 | 2008-05-12 16:24:43.846 | pduarte | 5.5 | 4 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18731 | 2008-05-12 16:18:59.849 | pduarte | 5.4 | 5.4 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18730 | 2008-05-12 16:12:43.071 | pduarte | 5.5 | 5.5 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18729 | 2008-05-12 16:06:01.967 | pduarte | 5.5 | 6 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18728 | 2008-05-12 15:59:35.647 | pduarte | 5.5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. |
| 18727 | 2008-05-12 15:53:38.748 | pduarte | 5.5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18726 | 2008-05-12 15:46:32.851 | pduarte | 5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18725 | 2008-05-12 15:39:52.466 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure |
| 18724 | 2008-05-12 15:06:55.945 | pduarte | 5.5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18723 | 2008-05-12 14:59:38.354 | pduarte | 5 | 5 | 26 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18722 | 2008-05-12 14:52:55.532 | pduarte | -6 | 4 | 5 | PRECO failure. 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18721 | 2008-05-12 14:44:24.731 | pduarte | 5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18720 | 2008-05-12 14:36:58.553 | pduarte | 5 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18719 | 2008-05-12 14:25:22.072 | pduarte | 5 | 4 | 43 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18718 | 2008-05-12 14:17:29.346 | pduarte | 4 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,70x10^(-4)mbar. Pre-Programmed H and V field. |
| 18717 | 2008-05-12 14:07:04.15 | pduarte | 4 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18716 | 2008-05-12 14:00:02.358 | pduarte | 2.5 | 2.5 | 26 | FRAEP failure. 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18715 | 2008-05-12 13:54:06.048 | pduarte | 4 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,40x10^(-4)mbar. Pre-Programmed H and V field. |
| 18714 | 2008-05-12 13:46:12.767 | pduarte | 4 | 5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18713 | 2008-05-12 13:34:22.706 | pduarte | 3.9 | 4 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. |
| 18712 | 2008-05-12 13:27:20.898 | pduarte | 2 | 3 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18711 | 2008-05-12 13:21:09.165 | pduarte | 1 | 2.5 | 49 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |