| Session aim | Machine Conditioning | | Session day | 2008-05-16 | Operator | pduarte | | Session ID | ISTTOK_2008516_1 | Coordinator | pduarte |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 18842 | 2008-05-16 14:39:47.682 | pduarte | 1.5 | 8 | 1 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=2,40x10^(-4)mbar. Pre-Programmed H and V field. Emissive electrode as FILAMENT. | | 18841 | 2008-05-16 13:46:23.405 | pduarte | 0 | 0 | 0 | FILAMENT BROKE | | 18840 | 2008-05-16 13:37:30.702 | pduarte | 0 | 0 | 0 | FILAMENT BROKE | | 18839 | 2008-05-16 13:31:59.526 | pduarte | 0 | 0 | 0 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. RAKE and LANG. FILAMENT BROKE | | 18838 | 2008-05-16 13:20:08.711 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure | | 18837 | 2008-05-16 13:13:31.175 | pduarte | 0 | 0 | 0 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. RAKE and LANG. FILAMENT BROKE |
|