Session aimMachine conditioning. Ion beam tests.
Session day2008-05-29Operatorpduarte
Session IDISTTOK_2008529_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
189482008-05-29 16:07:20.218pduarte3.84.14940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189472008-05-29 16:01:51.056pduarte43.94940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189462008-05-29 15:48:29.881pduarte43.82640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189452008-05-29 15:38:33.303pduarte444940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189442008-05-29 15:31:00.773pduarte4.24.54940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189432008-05-29 15:23:23.924pduarte4.14.54940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189422008-05-29 15:12:53.532pduarte4.254940 turns primary. R = 0,2ohm. ELCO = 220V. P=2,20x10^(-4)mbar. Pre-Programmed H and V field.
189412008-05-29 15:06:15.709pduarte3.54.54940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189402008-05-29 14:56:42.353pduarte454940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189392008-05-29 14:50:12.424pduarte44.94940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189382008-05-29 14:44:11.156pduarte3.74.84940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189372008-05-29 14:36:46.553pduarte3.54.54940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
189362008-05-29 14:30:57.68pduarte00140 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Plasma Position node failure. Ion Beam.
189352008-05-29 14:24:32.538pduarte3.54.54940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189342008-05-29 14:05:55.285pduarte3.24.34940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
189332008-05-29 13:58:53.119pduarte00140 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Plasma Position node failure. Ion Beam.
189322008-05-29 13:51:29.424pduarte2.93.74940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189312008-05-29 13:44:58.666pduarte2.53.54940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189302008-05-29 13:37:30.203pduarte1.834940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189292008-05-29 13:31:12.365pduarte1.42.84940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. Ion Beam.
189282008-05-29 13:25:30.339pduarte1.22.64940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189272008-05-29 13:18:26.29pduarte0.92.14940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.