Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 18575 | 2008-05-02 15:25:56.74 | pduarte | 3.7 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field. |
| 18574 | 2008-05-02 15:20:13.474 | pduarte | 3.7 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field. |
| 18573 | 2008-05-02 15:13:55.348 | pduarte | 3.6 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18572 | 2008-05-02 15:06:38.159 | pduarte | 3.5 | 3.2 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18571 | 2008-05-02 14:57:57.42 | pduarte | 3.2 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18570 | 2008-05-02 14:52:25.444 | pduarte | 3 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18569 | 2008-05-02 14:41:04.637 | pduarte | 3 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 18568 | 2008-05-02 14:35:26.902 | pduarte | 2.7 | 2.8 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18567 | 2008-05-02 14:29:43.168 | pduarte | 2.5 | 2.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18566 | 2008-05-02 14:23:31.292 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure |
| 18565 | 2008-05-02 14:17:06.131 | pduarte | 2.4 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18564 | 2008-05-02 14:06:37.436 | pduarte | 1.9 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18563 | 2008-05-02 13:56:52.435 | pduarte | 1.7 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18562 | 2008-05-02 13:50:30.458 | pduarte | 1.7 | 2.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,10x10^(-4)mbar. Pre-Programmed H and V field. |
| 18561 | 2008-05-02 13:43:15.989 | pduarte | 1.4 | 2.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |
| 18560 | 2008-05-02 13:32:29.722 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure |
| 18559 | 2008-05-02 13:26:23.30 | pduarte | 1 | 2.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,00x10^(-4)mbar. Pre-Programmed H and V field. |