Session aimMachine Conditioning
Session day2008-05-30Operatorpduarte
Session IDISTTOK_2008530_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
189662008-05-30 15:10:42.249pduarte444940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189652008-05-30 15:02:17.784pduarte3.944940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189642008-05-30 14:55:57.683pduarte3.742640 turns primary. R = 0,2ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
189632008-05-30 14:50:27.353pduarte3.64.14940 turns primary. R = 0,2ohm. ELCO = 180V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field.
189622008-05-30 14:44:27.006pduarte3.644940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189612008-05-30 14:37:44.662pduarte3.544940 turns primary. R = 0,2ohm. ELCO = 180V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189602008-05-30 14:31:07.92pduarte3.74.54940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189592008-05-30 14:20:39.39pduarte3.64.54940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
189582008-05-30 14:13:32.339pduarte3.64.54940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field.
189572008-05-30 14:07:31.104pduarte3.53.84940 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
189562008-05-30 14:01:42.381pduarte344940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
189552008-05-30 13:44:31.375pduarte2.53.54940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189542008-05-30 13:37:29.315pduarte1.93.44940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189532008-05-30 13:27:31.859pduarte13.44940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189522008-05-30 13:18:53.659pduarte1.12.84940 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189512008-05-30 13:12:49.634pduarte000ELCO failure
189502008-05-30 13:07:02.375pduarte00140 turns primary. R = 0,2ohm. ELCO = 50V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
189492008-05-30 12:55:22.216pduarte0.92.82640 turns primary. R = 0,2ohm. ELCO = 220V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. TACCK failure.