Session aimMachine Conditioning
Session day2008-06-17Operatorpduarte
Session IDISTTOK_2008617_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
191872008-06-17 11:21:25.997pduarte2.53.39840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=16kHz
191862008-06-17 11:14:21.479pduarte2.53.39840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,70x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=16kHz
191852008-06-17 11:08:44.422pduarte2.23.29840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,55x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=8kHz
191842008-06-17 11:01:33.724pduarte23.29840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,55x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=32kHz
191832008-06-17 10:53:05.378pduarte1.93.19840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=32kHz
191822008-06-17 10:37:06.634pduarte1.63.19840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=8kHz
191812008-06-17 10:28:31.334pduarte1.539840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. Interferometer filter=16kHz
191802008-06-17 10:18:39.556pduarte1.42.89840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
191792008-06-17 10:07:56.676pduarte0.42.89840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
191782008-06-17 09:52:26.222pduarte0.52.89840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.