Session aimMachine Conditioning. Gundestrup tests
Session day2008-07-10Operatorpduarte
Session IDISTTOK_2008710_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
195382008-07-10 16:27:33.676pduarte3.43.54840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -180V bias.
195372008-07-10 16:21:53.868pduarte3.43.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -180V bias.
195362008-07-10 16:11:35.126pduarte3.53.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=90. Isat mode with -180V bias.
195352008-07-10 16:05:48.433pduarte3.43.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=90. Isat mode with -180V bias.
195342008-07-10 15:59:59.578pduarte3.23.44840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -180V bias.
195332008-07-10 15:54:24.913pduarte000Plasma Position node failure
195322008-07-10 15:14:34.56pduarte3.53.54840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -180V bias.
195312008-07-10 15:03:38.905pduarte3.53.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -180V bias.
195302008-07-10 14:56:47.634pduarte3.23.74840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,45x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -180V bias.
195292008-07-10 14:48:52.38pduarte3.13.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,45x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -180V bias.
195282008-07-10 14:37:54.231pduarte33.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,45x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=80. Isat mode with -180V bias.
195272008-07-10 14:30:25.646pduarte2.53.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,45x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=80. Isat mode with -180V bias.
195262008-07-10 14:17:28.258pduarte2.134840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,45x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=80. Isat mode with -180V bias.
195252008-07-10 14:11:48.255pduarte000Plasma Position node failure
195242008-07-10 14:02:39.404pduarte1.92.84240 turns primary. R = 0,2ohm. ELCO = 220V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -180V bias.
195232008-07-10 13:54:19.439pduarte1.232640 turns primary. R = 0,2ohm. ELCO = 220V. P=1,35x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -180V bias.
195222008-07-10 13:47:42.532pduarte00040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,25x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -180V bias.