Session aimMachine Conditioning. Gundestrup tests. Smaller Gundestrup
Session day2008-07-11Operatorpduarte
Session IDISTTOK_2008711_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
195642008-07-11 16:41:55.403pduarte3.434840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=90. Isat mode with -100V bias.
195632008-07-11 16:32:30.183pduarte3.334840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -100V bias.
195622008-07-11 16:25:04.028pduarte3.23.14840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=65. Isat mode with -100V bias.
195612008-07-11 16:19:16.659pduarte3.33.14840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=65. Isat mode with -100V bias.
195602008-07-11 16:12:10.979pduarte3.33.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -100V bias.
195592008-07-11 16:05:06.002pduarte3.33.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -100V bias.
195582008-07-11 15:59:42.991pduarte3.33.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=70. Isat mode with -100V bias.
195572008-07-11 15:53:39.72pduarte3.43.34840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195562008-07-11 15:47:22.923pduarte3.33.24840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195552008-07-11 15:41:01.462pduarte3.33.24840 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195542008-07-11 15:31:45.261pduarte3.23.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195532008-07-11 15:25:51.343pduarte33.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195522008-07-11 15:20:06.58pduarte33.54840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195512008-07-11 15:11:04.228pduarte2.93.44840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195502008-07-11 15:02:43.408pduarte1.734840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=75. Isat mode with -100V bias.
195492008-07-11 14:51:23.082pduarte2.73.44840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -100V bias.
195482008-07-11 14:43:53.631pduarte2.23.34840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -100V bias.
195472008-07-11 14:35:58.958pduarte1.93.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -100V bias.
195462008-07-11 14:27:19.686pduarte1.73.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. GUNDESTRUP on RAKE acquisition. GUND=85. Isat mode with -100V bias.
195452008-07-11 14:13:23.723pduarte1.53.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
195442008-07-11 14:06:36.355pduarte1.23.24840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
195432008-07-11 13:59:45.993pduarte12.94840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
195422008-07-11 13:53:07.493pduarte0.82.84840 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
195412008-07-11 13:47:00.542pduarte-0.722040 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
195402008-07-11 13:40:46.906pduarte00240 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
195392008-07-11 13:28:11.022pduarte000wrong settings