Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 19423 | 2008-07-03 16:24:59.248 | pduarte | 1.5 | 2.7 | 90 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=7300A=>valor=1600. AC |
| 19422 | 2008-07-03 16:12:35.695 | pduarte | 2.1 | 2.7 | 35 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=4200A=>valor=500. AC* |
| 19421 | 2008-07-03 16:02:53.662 | pduarte | 2 | 2.5 | 75 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=4200A=>valor=500 |
| 19420 | 2008-07-03 15:52:19.791 | pduarte | 2 | 2.6 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=4200A=>valor=500 |
| 19419 | 2008-07-03 15:45:39.538 | pduarte | 2 | 2.7 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=4600A=>valor=650 |
| 19418 | 2008-07-03 15:32:33.479 | pduarte | 1.9 | 2.7 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=5000A=>valor=750 |
| 19417 | 2008-07-03 15:25:55.113 | pduarte | 1.9 | 2.7 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=5000A=>valor=750 |
| 19416 | 2008-07-03 15:17:58.466 | pduarte | 1.6 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=7300A=>valor=1600 |
| 19415 | 2008-07-03 15:09:37.116 | pduarte | 1.6 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=7300A=>valor=1600 |
| 19414 | 2008-07-03 15:02:15.989 | pduarte | 1.6 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=7300A=>valor=1600 |
| 19413 | 2008-07-03 14:55:04.61 | pduarte | 1.5 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=7300A=>valor=1600 |
| 19412 | 2008-07-03 14:45:45.109 | pduarte | 1.7 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. Injector=65mm. ITOR=6700A=>valor=1400 |
| 19411 | 2008-07-03 14:39:32.087 | pduarte | 1.9 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Gallium. ITOR=6300A=>valor=1250 |
| 19410 | 2008-07-03 14:25:52.666 | pduarte | 2 | 2.9 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. ITOR=5900A=>valor=1100 |
| 19409 | 2008-07-03 14:18:22.992 | pduarte | 2 | 2.9 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. |
| 19408 | 2008-07-03 14:08:26.898 | pduarte | 2 | 3 | 97 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. AC* |
| 19407 | 2008-07-03 14:02:11.635 | pduarte | 1.9 | 3 | 97 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. |
| 19406 | 2008-07-03 13:56:01.503 | pduarte | 1.9 | 3 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. |
| 19405 | 2008-07-03 13:47:43.911 | pduarte | 1.9 | 2.9 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. With Gallium. Injector=65mm. |
| 19404 | 2008-07-03 13:40:42.458 | pduarte | 2 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19403 | 2008-07-03 13:33:27.959 | pduarte | 2 | 2.8 | 25 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |