| 19782 | 2008-09-26 16:03:53.564 | pduarte | 3.2 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=62,5. IR sensors on rake1 and rake2. Ga hotter. |
| 19781 | 2008-09-26 15:49:47.79 | pduarte | 0 | 0 | 0 | 40 turns primary. R = 0,2ohm. ELCO = 190V. Without gas injection. Pre-Programmed H and V field. Ga injector=65,5. IR sensors on rake1 and rake2. Ga hotter. |
| 19780 | 2008-09-26 15:41:39.426 | pduarte | 3.4 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=65,5. IR sensors on rake1 and rake2. Ga hotter. |
| 19779 | 2008-09-26 15:33:51.095 | pduarte | 3.4 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=68,5. IR sensors on rake1 and rake2. Ga hotter. |
| 19778 | 2008-09-26 15:16:26.459 | pduarte | 3.4 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Without Ga. IR sensors on rake1 and rake2. |
| 19777 | 2008-09-26 14:56:24.232 | pduarte | 3.4 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=68,5. IR sensors on rake1 and rake2. |
| 19776 | 2008-09-26 14:47:42.89 | pduarte | 0 | 0 | 0 | 40 turns primary. R = 0,2ohm. ELCO = 190V. without gas injection. Pre-Programmed H and V field. Ga injector=65,5. IR sensors on rake1 and rake2. |
| 19775 | 2008-09-26 14:39:03.17 | pduarte | 3.4 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. without Ga. IR sensors on rake1 and rake2. |
| 19774 | 2008-09-26 14:30:40.613 | pduarte | 3.3 | 3.5 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=65,5. IR sensors on rake1 and rake2. |
| 19773 | 2008-09-26 14:18:36.413 | pduarte | 3.3 | 3.6 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Ga injector=62,5. IR sensors on rake1 and rake2. |
| 19772 | 2008-09-26 14:10:49.396 | pduarte | 3.2 | 3.2 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19771 | 2008-09-26 14:03:23.479 | pduarte | 3.1 | 3.2 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19770 | 2008-09-26 13:56:42.821 | pduarte | 3.2 | 3.8 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19769 | 2008-09-26 13:48:46.82 | pduarte | 2.7 | 3.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19768 | 2008-09-26 13:41:16.585 | pduarte | 2.5 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19767 | 2008-09-26 13:21:04.968 | pduarte | 2.3 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19766 | 2008-09-26 13:12:38.454 | pduarte | 2 | 3.4 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19765 | 2008-09-26 13:02:36.354 | pduarte | 1.7 | 3.3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. |
| 19764 | 2008-09-26 12:53:22.042 | pduarte | 1.5 | 3 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,25x10^(-4)mbar. Pre-Programmed H and V field. |
| 19763 | 2008-09-26 12:41:42.50 | pduarte | 1.3 | 2.7 | 30 | 40 turns primary. R = 0,2ohm. ELCO = 220V. P=1,25x10^(-4)mbar. Pre-Programmed H and V field. |