Session aimToroidal Field Inverted. Machine conditioning.
Session day2009-10-12Operatorpduarte
Session IDISTTOK_20091012_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
237822009-10-12 16:10:35.255pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237812009-10-12 16:03:10.238pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237802009-10-12 15:53:03.266pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237792009-10-12 15:46:44.318pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237782009-10-12 15:31:38.578pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237772009-10-12 15:24:11.975pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237762009-10-12 15:18:17.662pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237752009-10-12 15:11:01.476pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237742009-10-12 14:58:48.319pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback.
237732009-10-12 14:48:25.849pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback
237722009-10-12 14:28:20.457pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback
237712009-10-12 14:21:18.454pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback
237702009-10-12 14:00:56.871pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback
237692009-10-12 13:43:34.098pduarte001IVERT failure. Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed H field. V field feedback