Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 23801 | 2009-10-13 16:38:15.319 | pduarte | 5.3 | 5 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. IVERT=360A. PD h-alpha on atca.b01 ch30 |
| 23800 | 2009-10-13 16:23:35.663 | pduarte | 5.5 | 5 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. IVERT=360A. PD on atca.b01 ch30 |
| 23799 | 2009-10-13 16:08:44.026 | pduarte | 5.5 | 5 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. IVERT=340A. PD on atca.b01 ch30 |
| 23798 | 2009-10-13 15:58:04.676 | pduarte | 5.5 | 5 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23797 | 2009-10-13 15:44:48.506 | pduarte | 5.5 | 5 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23796 | 2009-10-13 15:28:24.958 | pduarte | 5.5 | 4.5 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23795 | 2009-10-13 15:09:03.379 | pduarte | 5.5 | 4.5 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23794 | 2009-10-13 14:59:49.955 | pduarte | 5.2 | 4.5 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23793 | 2009-10-13 14:48:33.505 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure. Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23792 | 2009-10-13 14:36:19.083 | pduarte | 5.5 | 4.5 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23791 | 2009-10-13 14:25:53.418 | pduarte | 5.5 | 4 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23790 | 2009-10-13 14:18:14.452 | pduarte | 4.5 | 4 | 28 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23789 | 2009-10-13 14:08:22.043 | pduarte | 5 | 4 | 52 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. V field feedback. |
| 23788 | 2009-10-13 14:00:48.496 | pduarte | 4 | 3.5 | 44 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23787 | 2009-10-13 13:53:16.893 | pduarte | 2 | 2 | 10 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23786 | 2009-10-13 13:45:40.59 | pduarte | 0 | 0 | 2 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23785 | 2009-10-13 13:35:00.667 | pduarte | 0 | 0 | 2 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,80x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23784 | 2009-10-13 13:27:06.48 | pduarte | 0 | 0 | 2 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,80x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |
| 23783 | 2009-10-13 13:19:20.761 | pduarte | 0 | 0 | 1 | Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,80x10^(-4)mbar. Pre-Programmed H field. Pre-programmed V field. |