Session aimToroidal Field Inverted. Old IVERT power supply. Machine conditioning
Session day2009-10-15Operatorpduarte
Session IDISTTOK_20091015_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
238122009-10-15 16:07:00.68pduarte3.32.828Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed V and H field.
238112009-10-15 16:01:32.358pduarte2.51.527Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed V and H field.
238102009-10-15 15:54:52.104pduarte-3320Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,75x10^(-4)mbar. Pre-Programmed V and H field. Old IVERT power supply
238092009-10-15 15:48:11.227pduarte002Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed V and H field. Old IVERT power supply
238082009-10-15 15:40:21.458pduarte001Toroidal Field Inverted. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=0,85x10^(-4)mbar. Pre-Programmed V and H field. Old IVERT power supply