Session aimMachine conditioning. E-Probes
Session day2009-10-21Operatorpduarte
Session IDISTTOK_20091021_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
238602009-10-21 15:47:12.385pduarte532840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238592009-10-21 15:41:32.806pduarte532840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238582009-10-21 15:28:46.573pduarte4.63.52840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238572009-10-21 15:17:07.124pduarte53.52840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238562009-10-21 15:08:50.421pduarte53.52840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238552009-10-21 15:02:35.775pduarte53.22840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238542009-10-21 14:55:56.839pduarte532840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238532009-10-21 14:46:33.719pduarte532840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238522009-10-21 14:37:03.482pduarte2.5110IVERT and IHORIZ failure
238512009-10-21 14:30:50.593pduarte5.13.52840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238502009-10-21 14:22:46.339pduarte5.132840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238492009-10-21 14:16:44.052pduarte532840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238482009-10-21 14:07:18.297pduarte4.732840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238472009-10-21 14:01:13.281pduarte4.542840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB1.ch31. Poloidal E-probes on.
238462009-10-21 13:31:11.309pduarte3.93.52840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,00x10^(-4)mbar. Pre-Programmed V and H field.