Session aimMachine conditioning. E-Probes
Session day2009-11-18Operatorpduarte
Session IDISTTOK_20091118_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
240732009-11-18 17:51:04.593pduarte4.23.82840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240722009-11-18 17:45:30.104pduarte4.23.92840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240712009-11-18 17:39:31.713pduarte4.23.82840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240702009-11-18 17:33:19.788pduarte4.43.92840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240692009-11-18 17:27:17.751pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240682009-11-18 17:21:22.504pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240672009-11-18 17:14:30.736pduarte4.542840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240662009-11-18 17:08:32.288pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240652009-11-18 17:02:13.818pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240642009-11-18 16:56:10.885pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,60x10^(-4)mbar. Pre-Programmed V and H field.
240632009-11-18 16:49:12.525pduarte4.542840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240622009-11-18 16:43:20.895pduarte4.442840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240612009-11-18 16:35:54.364pduarte4.13.92840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240602009-11-18 16:27:58.681pduarte00240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Plasma Position node failure.
240592009-11-18 16:18:44.50pduarte4.43.93740 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240582009-11-18 16:12:27.615pduarte4.23.92840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240572009-11-18 16:05:23.718pduarte3.73.72840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed V and H field.
240562009-11-18 15:54:46.564pduarte000PRECO tests
240552009-11-18 15:48:59.794pduarte000PRECO tests
240542009-11-18 15:41:24.798pduarte000PRECO failure
240532009-11-18 15:33:52.958pduarte000PRECO failure
240522009-11-18 15:28:27.093pduarte000PRECO failure
240512009-11-18 15:17:26.671pduarte4.63.73740 turns primary. R = 0,4ohm. ELCO = 200V. P=1,20x10^(-4)mbar. Pre-Programmed V and H field. PD on atcaB3.ch27
240502009-11-18 15:09:35.834pduarte4.13.35240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
240492009-11-18 14:58:11.011pduarte3.73.32840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
240482009-11-18 14:47:02.475pduarte2.72.42840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,10x10^(-4)mbar. Pre-Programmed V and H field.
240472009-11-18 14:38:38.967pduarte00140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,10x10^(-4)mbar.