Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
208352009-01-14 16:56:42.174pduarte3.53.56140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208342009-01-14 16:45:21.268pduarte3.53.53340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208332009-01-14 16:31:23.188pduarte3.53.53340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208322009-01-14 16:16:28.05pduarte3.53.83340 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208312009-01-14 16:03:58.892pduarte3.53.56140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf. Vertical field step from 20 to 33ms.
208302009-01-14 15:54:35.729pduarte3.63.26140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208292009-01-14 15:45:12.298pduarte3.53.46140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208282009-01-14 15:34:26.20pduarte3.43.26140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208272009-01-14 15:23:42.914pduarte336140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208262009-01-14 15:11:35.544pduarte2.736140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208252009-01-14 15:01:20.476pduarte2.32.96140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208242009-01-14 14:47:57.019pduarte1.82.96140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208232009-01-14 14:38:01.90pduarte1.62.86140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. Electric probes on Vf.
208222009-01-14 14:30:12.644pduarte1.12.96140 turns primary. R = 0,2ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.