Session aimE-probes tests
Session day2009-12-14Operatorpduarte
Session IDISTTOK_20091214_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
243452009-12-14 16:44:49.29pduarte3.92.93840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=31,5cm
243442009-12-14 16:34:26.546pduarte000PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=31,5cm
243432009-12-14 16:27:58.638pduarte3.934040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=31,5cm
243422009-12-14 16:22:03.414pduarte4.12.95040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=31cm
243412009-12-14 16:16:08.724pduarte4.134040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=31cm
243402009-12-14 15:56:59.566pduarte4.132840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=30,5cm
243392009-12-14 15:51:08.025pduarte4.232840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=30,5cm
243382009-12-14 15:44:20.622pduarte4.332840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=30cm
243372009-12-14 15:37:06.299pduarte4.43.25040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,8x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=30cm
243362009-12-14 15:30:49.441pduarte4.33.22840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=29,5cm
243352009-12-14 15:24:50.553pduarte4.53.22840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=29,5cm
243342009-12-14 15:18:15.207pduarte4.43.25040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=29cm
243332009-12-14 15:11:26.159pduarte4.53.32840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. poloidal e-probe=29cm
243322009-12-14 14:59:50.438pduarte4.432840 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
243312009-12-14 14:50:38.06pduarte4.335040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field.
243302009-12-14 14:43:45.269pduarte4.43.52840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,5x10^(-4)mbar. Pre-Programmed V and H field.
243292009-12-14 14:37:48.365pduarte4.23.52840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field.
243282009-12-14 14:24:33.33pduarte4.13.42840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field.
243272009-12-14 14:18:10.737pduarte32.52740 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field.
243262009-12-14 14:10:38.413pduarte2.521640 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field.