Session aimGallium exposition
Session day2009-12-09Operatorpduarte
Session IDISTTOK_2009129_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
242782009-12-09 17:31:15.491pduarte000Software shots - Gallium and IR sensor tests. Ch1 and Ch2 on atcaB2.ch14 and atcaB2.ch15
242772009-12-09 17:24:50.968pduarte000Software shots - Gallium and IR sensor tests. Ch1 and Ch2 on atcaB2.ch14 and atcaB2.ch15.
242762009-12-09 17:09:48.01pduarte000without gas. no acquisition
242752009-12-09 17:03:27.554pduarte2.52.82840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242742009-12-09 16:52:39.68pduarte0010some triggers failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242732009-12-09 16:45:55.382pduarte000Software shot - Ga but no acquisition
242722009-12-09 16:38:43.066pduarte3.93.45240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242712009-12-09 16:32:43.575pduarte3.93.45240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242702009-12-09 16:25:29.503pduarte3.93.45240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,6x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242692009-12-09 16:16:36.03pduarte4.13.35240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242682009-12-09 16:10:24.012pduarte43.55240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242672009-12-09 16:04:19.086pduarte3.83.35240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,4x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242662009-12-09 15:58:01.167pduarte3.73.35240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242652009-12-09 15:50:23.107pduarte000Software shots - Gallium and IR sensor tests. Ch1 and Ch2 on atcaB2.ch14 and atcaB2.ch15.
242642009-12-09 15:43:39.478pduarte3.83.45240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242632009-12-09 15:33:15.695pduarte000Software shots - Gallium and IR sensor tests. Ch1 and Ch2 on atcaB2.ch14 and atcaB2.ch15.
242622009-12-09 15:26:54.02pduarte3.73.35240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242612009-12-09 15:19:33.559pduarte3.535240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242602009-12-09 15:13:20.087pduarte32.85240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242592009-12-09 15:07:16.475pduarte000PRECO failures
242582009-12-09 15:01:20.858pduarte2.32.65240 turns primary. R = 0,4ohm. ELCO = 200V. P=1,2x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242572009-12-09 14:55:25.546pduarte1.62.54740 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242562009-12-09 14:49:55.256pduarte12.54840 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242552009-12-09 14:43:49.933pduarte0.71.71040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242542009-12-09 14:36:40.066pduarte000PRECO failures. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition
242532009-12-09 14:29:34.063pduarte-0.52.51040 turns primary. R = 0,4ohm. ELCO = 180V. P=1,1x10^(-4)mbar. Pre-Programmed V and H field. Ga exposition