Session aimMachine conditioning. European research doctarate visits
Session day2009-02-10Operatorpduarte
Session IDISTTOK_2009210_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
211622009-02-10 16:32:43.507pduarte2.61.43340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211612009-02-10 16:20:38.005pduarte2.61.43340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211602009-02-10 16:09:21.578pduarte2.41.63340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211592009-02-10 16:03:42.196pduarte000PRECO failure
211582009-02-10 15:56:54.172pduarte2.51.43340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211572009-02-10 15:49:26.775pduarte2.41.93340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211562009-02-10 15:40:05.871pduarte2.41.43340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211552009-02-10 15:30:23.017pduarte21.43340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211542009-02-10 15:23:16.096pduarte1.81.52740 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211532009-02-10 15:11:32.259pduarte1.51.53340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211522009-02-10 15:04:50.816pduarte001ELCO circuit breaker failure
211512009-02-10 14:53:45.311pduarte1.51.53340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211502009-02-10 14:42:46.382pduarte11840 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211492009-02-10 11:50:42.12pduarte2.523340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211482009-02-10 11:25:12.849pduarte2.323340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211472009-02-10 10:57:33.523pduarte2.322640 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211462009-02-10 10:43:36.898pduarte000PRECO failure
211452009-02-10 10:35:35.184pduarte323340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211442009-02-10 10:28:01.929pduarte000PRECO failure
211432009-02-10 10:18:56.58pduarte3.22.33340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211422009-02-10 10:11:36.231pduarte3.22.23340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211412009-02-10 10:04:13.218pduarte326140 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211402009-02-10 09:57:23.764pduarte-322040 turns primary. R = 0,4ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
211392009-02-10 09:51:02.441pduarte000triggers failure
211382009-02-10 09:43:41.349pduarte2.51.53340 turns primary. R = 0,4ohm. ELCO = 170V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
211372009-02-10 09:33:10.684pduarte21.56140 turns primary. R = 0,4ohm. ELCO = 170V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.