Session aimMachine conditioning. Electrode tests.
Session day2009-02-13Operatorpduarte
Session IDISTTOK_2009213_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
212132009-02-13 15:57:06.673pduarte4.23.43340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212122009-02-13 15:45:35.301pduarte4.13.43340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212112009-02-13 15:36:27.327pduarte43.43340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212102009-02-13 15:19:36.852pduarte43.53340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212092009-02-13 15:10:50.581pduarte3.63.23340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212082009-02-13 15:04:49.12pduarte001ELCO circuit breaker failure
212072009-02-13 14:55:58.11pduarte4.33.43340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212062009-02-13 14:48:59.312pduarte43.34340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field.
212052009-02-13 14:40:47.445pduarte3.634640 turns primary. R = 0,4ohm. ELCO = 190V. P=1,80x10^(-4)mbar. Pre-Programmed H and V field.
212042009-02-13 14:30:28.018pduarte3.633340 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
212032009-02-13 14:11:14.717pduarte2.722840 turns primary. R = 0,4ohm. ELCO = 190V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field.
212022009-02-13 13:38:51.31pduarte22.56140 turns primary. R = 0,4ohm. ELCO = 190V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.