| 21316 | 2009-02-20 12:34:19.957 | pduarte | 3.8 | 3.3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=55. Electrode=60. VACPL=80V |
| 21315 | 2009-02-20 12:27:30.808 | pduarte | 4 | 3.2 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=85. Electrode=60. VACPL=80V |
| 21314 | 2009-02-20 12:22:12.296 | pduarte | 3.9 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=60. Electrode=60. VACPL=80V |
| 21313 | 2009-02-20 12:16:20.349 | pduarte | 4 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=80V |
| 21312 | 2009-02-20 12:09:10.232 | pduarte | 4 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=80V |
| 21311 | 2009-02-20 12:03:36.625 | pduarte | 4 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V. |
| 21310 | 2009-02-20 11:53:06.99 | pduarte | 3.9 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V. |
| 21309 | 2009-02-20 11:44:49.955 | pduarte | 4 | 3.4 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=80. Electrode=60. VACPL=75V. |
| 21308 | 2009-02-20 11:37:59.76 | pduarte | 4 | 3.4 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=80. Electrode=60. VACPL=75V. |
| 21307 | 2009-02-20 11:30:55.142 | pduarte | 4.1 | 3.5 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V. |
| 21306 | 2009-02-20 11:23:35.568 | pduarte | 3.9 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V. |
| 21305 | 2009-02-20 11:16:15.091 | pduarte | 3.9 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=75V. |
| 21304 | 2009-02-20 11:08:14.356 | pduarte | 3.8 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=75V. |
| 21303 | 2009-02-20 11:00:50.952 | pduarte | 3.7 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=75V. |
| 21302 | 2009-02-20 10:53:52.238 | pduarte | 3.5 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=70V. |
| 21301 | 2009-02-20 10:46:49.007 | pduarte | 3.3 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=70V. |
| 21300 | 2009-02-20 10:41:19.173 | pduarte | 0 | 0 | 0 | PRECO failure |
| 21299 | 2009-02-20 10:35:48.398 | pduarte | 0 | 0 | 0 | PRECO failure |
| 21298 | 2009-02-20 10:27:42.352 | pduarte | 3.2 | 3 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. |
| 21297 | 2009-02-20 10:22:13.464 | pduarte | 0 | 0 | 0 | PRECO failure |
| 21296 | 2009-02-20 10:14:52.592 | pduarte | 3 | 2.7 | 33 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. |
| 21295 | 2009-02-20 10:09:24.637 | pduarte | 0 | 0 | 0 | PRECO failure |
| 21294 | 2009-02-20 09:55:42.736 | pduarte | 2.5 | 2.5 | 61 | 40 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. |