Session aimMachine conditioning. Electric probes
Session day2009-02-20Operatorpduarte
Session IDISTTOK_2009220_1Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
213162009-02-20 12:34:19.957pduarte3.83.33340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=55. Electrode=60. VACPL=80V
213152009-02-20 12:27:30.808pduarte43.23340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=85. Electrode=60. VACPL=80V
213142009-02-20 12:22:12.296pduarte3.933340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=60. Electrode=60. VACPL=80V
213132009-02-20 12:16:20.349pduarte433340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=80V
213122009-02-20 12:09:10.232pduarte433340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=80V
213112009-02-20 12:03:36.625pduarte433340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V.
213102009-02-20 11:53:06.99pduarte3.933340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V.
213092009-02-20 11:44:49.955pduarte43.43340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=80. Electrode=60. VACPL=75V.
213082009-02-20 11:37:59.76pduarte43.43340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=80. Electrode=60. VACPL=75V.
213072009-02-20 11:30:55.142pduarte4.13.53340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V.
213062009-02-20 11:23:35.568pduarte3.933340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=75. Electrode=60. VACPL=75V.
213052009-02-20 11:16:15.091pduarte3.933340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=75V.
213042009-02-20 11:08:14.356pduarte3.833340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=65. Electrode=60. VACPL=75V.
213032009-02-20 11:00:50.952pduarte3.733340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=75V.
213022009-02-20 10:53:52.238pduarte3.533340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=70V.
213012009-02-20 10:46:49.007pduarte3.333340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60. VACPL=70V.
213002009-02-20 10:41:19.173pduarte000PRECO failure
212992009-02-20 10:35:48.398pduarte000PRECO failure
212982009-02-20 10:27:42.352pduarte3.233340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60.
212972009-02-20 10:22:13.464pduarte000PRECO failure
212962009-02-20 10:14:52.592pduarte32.73340 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic. RAKE=64. LANG=70. Electrode=60.
212952009-02-20 10:09:24.637pduarte000PRECO failure
212942009-02-20 09:55:42.736pduarte2.52.56140 turns primary. R = 0,4ohm. ELCO = 180V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. Poloidal array of electric probes on Ionic.