Session aimMachine conditioning. Cherenkov detector preliminary tests
Session day2009-02-26Operatorpduarte
Session IDISTTOK_2009226_2Coordinatorpduarte

Shot Time Operator Iplasma(kA) n(1018m-3) Duration (ms) Pre/post shot comments
213372009-02-26 17:16:37.606pduarte1.62.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=90mm. cherenkov_3 disconnected
213362009-02-26 17:00:15.551pduarte1.72.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=90mm
213352009-02-26 16:52:59.717pduarte1.62.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=90mm
213342009-02-26 16:43:01.165pduarte1.42.46140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=95mm
213332009-02-26 16:33:07.759pduarte1.32.46140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. CHERENKOV=95mm
213322009-02-26 16:27:40.883pduarte001Plasma Position node trigger failure
213312009-02-26 16:00:18.629pduarte1.62.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
213302009-02-26 15:51:06.733pduarte1.52.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
213292009-02-26 15:43:25.401pduarte1.32.46140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
213282009-02-26 15:33:12.273pduarte1.12.46140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field.
213272009-02-26 15:25:42.831pduarte12.56140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
213262009-02-26 15:18:11.285pduarte001ELCO circuit breaker failure
213252009-02-26 15:03:07.71pduarte12.36140 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
213242009-02-26 14:51:13.303pduarte-12.53040 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
213232009-02-26 14:43:38.749pduarte-0.82.726PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
213222009-02-26 14:35:57.149pduarte-0.72.515PRECO failure. 40 turns primary. R = 0,4ohm. ELCO = 200V. P=1,30x10^(-4)mbar. Pre-Programmed H and V field.
213212009-02-26 14:27:41.074pduarte00540 turns primary. R = 0,4ohm. ELCO = 180V. P=1,20x10^(-4)mbar. Pre-Programmed H and V field.