| Session aim | Machine conditioning | | Session day | 2009-02-02 | Operator | pduarte | | Session ID | ISTTOK_200922_1 | Coordinator | pduarte |
|
Shot
|
Time
|
Operator
|
Iplasma(kA)
|
n(1018m-3)
|
Duration (ms)
|
Pre/post shot comments
|
| 21074 | 2009-02-02 16:15:48.847 | pduarte | 4.8 | 3.7 | 33 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=2,10x10^(-4)mbar. Pre-Programmed H and V field. | | 21073 | 2009-02-02 16:07:25.488 | pduarte | 4.8 | 3.8 | 33 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=2,00x10^(-4)mbar. Pre-Programmed H and V field. | | 21072 | 2009-02-02 16:01:35.089 | pduarte | 4.5 | 3.5 | 33 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,85x10^(-4)mbar. Pre-Programmed H and V field. | | 21071 | 2009-02-02 15:54:06.588 | pduarte | 4 | 3.5 | 33 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. | | 21070 | 2009-02-02 15:46:31.068 | pduarte | 4.6 | 3.7 | 44 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. | | 21069 | 2009-02-02 15:36:50.478 | pduarte | 4.4 | 3.7 | 44 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,60x10^(-4)mbar. Pre-Programmed H and V field. | | 21068 | 2009-02-02 15:20:22.057 | pduarte | 0 | 0 | 0 | ELCO circuit breaker failure | | 21067 | 2009-02-02 15:08:45.463 | pduarte | 4.5 | 3.5 | 61 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. | | 21066 | 2009-02-02 14:57:58.436 | pduarte | 4.3 | 3.4 | 61 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. | | 21065 | 2009-02-02 14:44:10.328 | pduarte | 3.6 | 3 | 61 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,50x10^(-4)mbar. Pre-Programmed H and V field. | | 21064 | 2009-02-02 14:33:14.842 | pduarte | 2.5 | 2.3 | 61 | 40 turns primary. R = 0,2ohm. ELCO = 170V. P=1,40x10^(-4)mbar. Pre-Programmed H and V field. |
|